PT-104 Platinum Resistance Data Logger

PT-104


PT-104 Platinum Resistance Data Logger



PT-104 Price

PT-104 Datasheet

The PT-104 is a 4-channel temperature measuring data logger. It offers the ultimate in resolution (0.001 °C) and accuracy (0.01 °C). Along with temperature it can also be used to measure resistance and voltage.

Accuracy and Resolution

Although accurate temperature sensors are widely available, it has been difficult to take advantage of them due to errors caused by the measuring device. Your PT-104 however, is inherently accurate due to its innovative design. Rather than relying on voltage references (which tend to be temperature sensitive) it uses ‘reference’ resistors which are extremely stable (low temperature co-efficient and drift). The exact value of each resistor is stored in an EEPROM to provide the ultimate in accuracy (yearly re-calibration is recommended). A high-performance 24-bit ADC is used to achieve the 0.001 °C resolution.

Temperature

Your PT-104 measures temperature using platinum resistance thermometers (PRTs). Both common industry standards (PT100 and PT1000) are supported. The unit is compatible with 2, 3 and 4 wire sensors (4 wire PT100 sensors are recommended for accurate measurements). A wide range of PT100 sensors are available for use with your PT-104.

Data Logger Software



PT-104 Screw Terminal Adapter



Get your
PT-104 quotation today.





Related Links

PicoLog DAQ Software  |  Data Loggers




(All trademarks acknowledged) E. & O. E.

Resistance

When measuring resistance, your PT-104 uses a four-wire circuit to give the greatest possible accuracy.

Two resistance ranges are available (0 to 375 ohms and 0 to 10,000 ohms). The unit is calibrated for 0 to 375 ohms so this range should be used for accurate measurements.

Voltage

For voltage measurements, each input connector can be treated as a differential input with ground, or two single-ended inputs. Both inputs must be zero volts or above, though it does not matter which input has the higher voltage.

Two voltage ranges are available (0 to 115 mV and 0 to 2500 mV). For the most accurate measurements use the 0 to 2500 mV range.

PT-104 Screw Terminal Adapter

The PT-104 Screw Terminal Adapter is an accessory for the PT-104 Platinum Resistance Data Logger. The adapter allows PT-100 probes that are not fitted with a mini-DIN connector to be used with the data logger without the need for any soldering.

The adapter is suitable for use with the following size of wire:

  • 2.5 mm2 solid
  • 1.5 mm2 stranded
  • 14-22 AWG

Data Logging Software

Your PT100 data logger is supplied with PicoLog data logging software. PicoLog will automatically detect which sensor is connected and will display readings in the correct units. Also supplied is a software development kit. The SDK contains a range of software drivers and example code that you can use to write your own software or to use your PT-104 data logger with third-party software.

Need to measure more channels ?

Your PT-104 is capable of measuring up to 4 channels at once. Need more channels? No problem. Using PicoLog you can connect up to 10 PT-104s to one PC — giving you a potential 40-channel PT100 data logger. Alternatively you can use your PT-104 logger with up to 19 other Pico data loggers, such as the PicoLog 1000 multi-channel data logger, to create your own custom data acquisition system.

The ultimate in portability

With both USB and Ethernet interfaces your PT-104 can be used in a variety of situations. If you need a portable solution that can be used at various locations and is fast to set up and use, simply connect your laptop to the PT-104 by USB. Need to monitor a situation over a period of hours or days, or from a remote location? Plug your PT-104 into a spare port on your network and then access it remotely either from your LAN or over the internet (using Power over Ethernet (PoE) technology means that you don’t even need a separate power supply).

When accuracy is paramount

The PT-104 platinum resistance data logger gives you the ultimate in resolution and accuracy. You can use it to measure temperature, voltage and resistance. Having both USB and Ethernet interfaces gives you the choice of how you connect and power your PT-104, along with the ability to access the PT-104 remotely over a LAN or the internet. When the accuracy of your temperature measurements is paramount the PT-104 is what you need.

PT-104 Platinum Resistance Data Logger - Features

  • Measures temperature, resistance and voltage
  • High resolution and accuracy
  • No power supply required
  • Supports 2,3 and 4-wire sensors
  • USB and Ethernet interfaces
  • Run multiple units on a single PC
  • Works with PT100 and PT1000 sensors

Ask for PT-104 detailed specification.